Application
Specifications:
MODULE
|
3528
|
wavelength
|
1310nm/1550nm
±20nm
|
Applicable Fiber
|
Single-mode
|
Dynamic Range1
|
28/26dB
|
Distance Measurement Accuracy
|
±(1m + sample space + 0.003% * measurement distance)
|
Event Dead Zone2
|
≤1.6m
|
Sampling Resolution
|
0.25, 0.5, 1, 2, 4, 8, 16m
|
Distance Range
|
4, 8, 16, 32, 64, 128, 256km
|
Pulse width
|
10, 30, 80, 160, 320, 640, 1280, 5120, 10240ns
|
Loss threshold
|
0.01dB
|
Sampling points
|
65534
|
Linearity
|
0.05dB/dB
|
Memory capacity
|
≥800 Traces
|
IOR setting
|
1.00000∼2.00000
|
Display
|
Color LCD (touch screen)
|
Interface
|
USB, Min-USB
|
VFL
|
650nm±10nm, 2mW(typical); CW/1Hz
|
Language
|
English
|
Optical Connector
|
FC/UPC (universal connector)
|
Power Supply
|
DC:15V∼20V(3A), (AC adapter 100∼240V,50/60Hz,1.5A),Built-in Lithium battery:4400mAh,7.4V,operating time≥10 hours33
|
Dimensions
|
210mm*100mm*60mm
|
Weight
|
about 1kg
|
Note1:pulse width 10240ns, average times≥300,SNR=1,23℃±2℃;
Note2:Pulse width:10 ns, terminal reflection loss: ≥40dB, typical;
Note3:Low brightness, exclude measuring.
Product Down Load